Technical Description: The apparatus consists of a pipeline that contains one Bend meter. The pressure tapings from the Bend meter is taken to differential manometer to measure pressure difference. Present set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump etc. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different flow rates. Flow rate of water is measured with the help of measuring tank and stop watch.

LEARNING OBJECTS/EXPERIMENTATION:To demonstrate the use of Bend meter as flow meter.To determine co-efficient of discharge for given Bend meter.

REQUIRMENT FOR OPERATION: Electricity supply: Single Phase, 220 VAC, 50 Hz, 5-15 amp combined socket with earth connection.Water Supply (Initial Fill).Floor Drain required.Floor Area required: 1.5 m x 0.75 m Mercury (Hg) for manometer (250 gm).

TECHNICAL SPECIFICATION: Bend meter : Material Stainless steel Compatible to 1” Dia. Pipe.Water Circulation : FHP Pump, Crompton makeFlow Measurement : Using Measuring Tank (Capacity 25 Ltrs. (approx.))and Electronic Stop WatchSump Tank : Capacity 50 Ltrs. (approx.)Control Panel Comprises of :Standard make On/Off Switch, Mains Indicator, etc.Instruction Manual : An ENGLISH instruction manual will be provided along with the Apparatus Tanks will be made of Stainless Steel.The whole set-up is well designed and arranged in a good quality painted structure.

Control Panel:Standard make on/off switch, Mains Indicator etc.

Scope of Delivery:1 Self-contained “BEND METER TEST RIG” Apparatus1 Instruction Manual consisting of experimental procedures, block diagram etc.

Yes! I am Interested

Losses Due To Friction In Pipe Lines

REQUEST CALLBACK

Ask for Price

Technical Description:

The setup consists of 2 pipes of different diameters, which are connected in parallel. Pressure tapings are provided on each pipe to measure the pressure losses with the help of a Differential Manometer. Control valves are fitted on each pipe, which enables to use one pipe at a time for experiment. Present set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump etc. Flow control valve And by-pass valve are fitted in water line to conduct the Experiment on different flow rates. Flow rate of water is measured with the help of measuring tank and stop watch.

LEARNING OBJECTS/EXPERIMENTATION:

To determine the losses due to fiction in pipes.
To determine the friction factor for Darcy We is back equation.
REQUIRMENT FOR OPERATION:
Water Supply.
Drain.
Electricity 0.5 kW, 220V AC, Single Phase.
Floor Area 1.5 x 0.75 m.

TECHNICAL SPECIFICATION:

Pipe Test Section: (i) Dia ½”, Length : 1m, Material G.I.
(ii) Dia ¾”, Length: 1.25m, Material G.I.
Water Circulation: FHP Pump, Crompton/godrej/G.E makes.
Flow Measurement: Using Measuring Tank with Piezometer, Capacity 25 Ltrs.
Sump Tank: Capacity 50 Ltrs.
Stop Watch: Electronic.
Control Panel Comprises of :
Standard make On/Off Switch, Mains Indicator, etc.
Instruction Manual : An ENGLISH instruction manual will be provided along
with the Apparatus Tanks will be made of Stainless Steel.
The whole set-up is well designed and arranged in a good quality painted structure.

Control Panel:

Standard make on/off switch, Mains Indicator etc.

Scope of Delivery:

1 Self-contained “ LOSSES DUE TO FRICTION IN PIPE LINES” Apparatus
1 Instruction Manual consisting of experimental procedures, block diagram etc.

Yes! I am Interested

Study Of Pressure Measurement

REQUEST CALLBACK

Ask for Price

Technical Description:

The set-up consists of different pressure measurement devices fitted in a pipe line, in which an Orifice is fitted to create the pressure difference. Present set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump etc. Flow control valve and by-pass valve are fitted in water line.

LEARNING OBJECTS/EXPERIMENTATION:

  • To demonstrate the working of different pressure measuring devices.

  • To measure the pressure and pressure difference by pressure gauge, single column manometer, U Tube manometer & Inclined tube manometer.

REQUIRMENT FOR OPERATION:

  • Electricity Supply: Single phase, 220 VAC, 50 Hz, 5-15 amp. Combined socket with earth connection.
  • Water Supply (Initial fill)
  • Floor Drain required.
  • Floor Area Required: 1.5 m x 0.75 m
  • Mercury (Hg) for manometer (750 gm).

TECHNICAL SPECIFICATION:

  • Single Well Manometer: Single Tube Type.
  • Differential Manometer: U Tube Type.
  • Sensitive Manometer. : Inclined Tube Type
  • Pressure Gauge. : Bourdon Type
  • Water Circulation: FHP Pump, Champion makes.
  • Sump Tank: Capacity 60 Ltrs.
  • Control Panel Comprises of:
  • Standard make On/Off Switch, Mains Indicator, etc.
  • Instruction Manual: An ENGLISH instruction manual will be provided along
  • With the Apparatus Tanks will be made of Stainless Steel.
  • The whole set-up is well designed and arranged in a good quality painted structure.

Control Panel:

  • Standard make on/off switch, Mains Indicator etc.

Scope of Delivery:

  • 1 Self-contained “STUDY OF PRESSURE MEASUREMENT” Apparatus
  • 1 Instruction Manual consisting of experimental procedures, block diagram etc.

Yes! I am Interested

Venturi Meter, Orifice Meter Rota Meter Test Rig

REQUEST CALLBACK

Ask for Price

Technical Description: The apparatus consists of three pipelines emerging out from a common manifold. One pipe line contain a Venturimeter, second contains an Orifice and third pipe line contains a Rota meter. The pressure tapings from the Venturimeter and Orifice meter are taken to differential manometer to measure pressure difference. The Venturimeter, Orifice meter and Rota meter are connected in parallel and any one of them can be put in operation by operating valves provided at the downstream. Present set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different flow rates. Flow rate of water is measured with the help of measuring tank & stop watch.

LEARNING OBJECTS/EXPERIMENTATION:
  • To determine the co-efficient of discharged through Venturimeter and orifice meter.
  • To measure discharge through Venturimeter, Orifice meter and Rotameter
  • To calibrate the Rotameter.
REQUIRMENT FOR OPERATION: Electricity supply: Single Phase, 220 V AC, 50 Hz, 5-15 amp combined socket with earth connection.Water Supply (Initial Fill).Floor Drain required.Floor Area Required: 1.5 m x 0.75 m.

TECHNICAL SPECIFICATION:
  • Venturimeter: Material Clear Acrylic compatible to 1”Dia. Pipe.
  • Orificemeter: Orifice plate made of Stainless Steel and housing made of Clear Acrylic compatible to 1” Dia. Pipe.
  • Rota meter: Compatible Range. Eureka makes.
  • Water Circulation: FHP Pump, Crompton makes.
  • Flow Measurement: Using Measuring Tank (Capacity 25 ltrs.) and Electronic Stop Watch.
  • Sump Tank: Capacity 50 Ltrs.
  • Control Panel Comprises of: Standard makes On/Off Switch, Mains Indicator, etc.
  • Instruction Manual: An ENGLISH instruction manual will be provided along With the Apparatus.
  • Tanks will be made of Stainless Steel.
  • The whole set-up is well designed and arranged in a good quality painted structure.

Control Panel:
  • Standard make on/off switch, Mains Indicator etc.

Scope of Delivery:
  • 1 Self-contained “VENTURIMETER, ORIFICEMETER & ROTAMETER TEST RIG” Apparatus
  • 1 Instruction Manual consisting of experimental procedures, block diagram etc.

Yes! I am Interested